Bay
Basic Info.
Model NO. | 4000361C99MC |
Arc-extinguishing Medium | Oil-immersed Type |
Installation | Insert |
Structure | MCB |
Poles Number | 1 |
Type | Fuse |
Function | Overcurrent Protection |
Certification | ISO9001-2000, TUV |
HS | 8535100000 |
Product Height | 14.9 in |
Standard | Germany DIN Standard |
Product Weight | 1.8 Lb |
Material of Fuse Wire | Silver |
Product Diameter | 2.88 in |
Shape | View The Pictures |
Usage | High Voltage Equipment |
Fusing Speed | FF |
Fusing Device | Link Break |
Model No. | 4000361c99mc |
Transport Package | Foam Carton and Wooden Packing |
Specification | 23Kv |
Trademark | Wuhuan or OEM |
Origin | Xi′ an China |
HS Code | 8535100000 |
Production Capacity | 80000 Per Month |
Packaging & Delivery
Package Size 44.00cm * 40.00cm * 35.00cm Package Gross Weight 25.000kgProduct Description
PRNT4-15.5, PRNT4-24, PRNT4-40.5 series of high-voltage fuses for overload protection of oil-immersed transformers are suitable for use in power systems with AC rated frequency of 50Hz and rated voltage of 15.5kV, 24kV and 40.5 kV respectively. As the overload protection protection element for power transformer and other power equipment, the fuse is installed in the transformer oil of American type box transformer or other box transformer, and can be co-boxed with transformer and load switch. The oil-immersed transformer overload protection high-voltage fuse can not be used alone, can be connected in series with the transformer backup protection high-voltage current-limiting fuse to form a full range of high-voltage current-limiting fuse. When the overload current exceeds the specified value for a certain period of time, the circuit is opened by the overload high-voltage fuse. When the short-circuit current passes through the fuse, the short-circuit current is opened by the backup high-voltage current-limiting fuse. The product can be widely used in the distribution protection of wind power generation, solar power generation, tide stream power generation and other equipment.This product consists of two parts: overload protection fuse and plug-in bracket.
We customize kinds of medium voltage and high voltage fuses according to customer 's requirements .Cooper series model number of ELSP current-limiting backup fuse :
8.3kv CBUC08030C100, CBUC08030C100M, CBUC08040C100, CBUC08040C100M, CBUC08050C100, CBUC08050C100M, CBUC08065C100, CBUC08065C100M, CBUC08080C100, CBUC08080C100M, CBUC08100C100, CBUC08100C100M, CBUC08125C100, CBUC08125C100M, CBUC08150D100, CBUC08150D100M, CBUC08165D100, CBUC08180D100, CBUC08180D100M, CBUC08250D100, CBUC08250D100M, CBUC09030C100, CBUC09030C100M, CBUC09040C100, CBUC09040C100M, CBUC09050C100, CBUC09050C100M, CBUC09065C100, CBUC09065C100M, 15kv, CBUC15030C100, CBUC15030C100M, CBUC15040C100, CBUC15040C100M, 3CBUC15050C100, CBUC15050C100M, CBUC15065C100, CBUC15065C100M, CBUC15080C100, CBUC15080C100M, CBUC15100C100, CBUC15100C100M, CBUC15125C100, CBUC15125C100M, CBUC15150D100, CBUC15150D100M, CBUC15165C10, CBUC15165D100, CBUC15180D100, CBUC15180D100M, 17.5kv CBUC17030C100, CBUC17030C100M, CBUC17040C100, CBUC17040C100M, CBUC17050C100, CBUC17050C100M, CBUC17065C100, CBUC17065C100M, 23kv CBUC23030C100, CBUC23030C100M, CBUC23040C100, CBUC23040C100M, CBUC23050C100, CBUC23050C100M, CBUC23065C100, CBUC23065C100M, CBUC23080C100, CBUC23080C100M, CBUC23100C100, CBUC23100C100M, CBUC23125D100, CBUC23150D100, CBUC23165D100, 38kv CBUC38050D100, CBUC38065D100, CBUC38080D100, CBUC38100D100, CBUC38120D100, CBUC38140D100 |
Fusing For Three-Phase Single Voltage Transformers | ||||
High VoltageRating | TransformerkVA | Assumed Impedance % | 38 kV Bay-O-Net Fuse(Cooper Power series) | 38 kV Back UpCurrent-Limiting Fuse(Cooper Power series ELSP) |
34,500Δ | 150 | 2 | 4000380C06CB | CBUC38050D100 |
225 | 3 | 4000380C06CB | CBUC38050D100 | |
300 | 3.50 | 4000380C06CB | CBUC38050D100 | |
500 | 4.00 | 4000380C08CB | CBUC38050D100 | |
750 | 5.75 | 4000380C10CB | CBUC38065D100 | |
1000 | 5.75 | 4000380C10CB | CBUC38065D100 | |
1100 | 5.75 | 4000380C11CB | CBUC38080D100 | |
1250 | 5.75 | 4000380C11CB | CBUC38080D100 | |
1500 | 5.75 | 4000380C12CB | CBUC38100D100 | |
1750 | 5.75 | 4000380C12CB | CBUC38100D100 | |
1850 | 5.75 | 4000380C12CB | CBUC38100D100 | |
2000 | 5.75 | 4000380C12CB | CBUC38100D100 | |
2250 | 5.75 | 4000380C14CB | CBUC38140D100 | |
2500 | 5.75 | 4000380C14CB | CBUC38140D100 | |
2850 | 5.75 | 4000380C14CB | CBUC38140D100 | |
3000 | 5.75 | 4000380C14CB | CBUC38140D100 | |
3200 | 5.75 | 4000380C14CB | CBUC38140D100 |
1. Model and meaning of China domestic BAY-O-NET fuse :2. This product is composed of overload protection fuse and fuse holder.2.1 Basic engineering data:
Model number | Rating current of fusible core (A) | Service enviornment | Rating breaking current (KA) |
PRNT4-15.5 PRNT4-24 PRNT4-40.5 | 5, 6.3, 10 , 16, 25, 40, 50, 63 100, 140 | in transformer oil | 2.5 |
Note:Dual fuse maximum 63A
2.2 See picture 1 for the size and installation of the overload protection fuse Picture 1,XRNT4-15.5 High voltage fuses for overload protection of oil immersed transformer .
2.3 See picture 2 and picture 3 for the dimension and installation of the plug-in fuse holder
3. Installation steps of fuse wire:4. Time-current characteristic curve of bay-o-net fuse as below :
Transformer capacity (KVA) | 12KV power system | 24KV power system | 40.5KV power system | |||
overload fuse | Backup current limiting fuse | overload fuse | Backup current limiting fuse | overload fuse | Backup current limiting fuse | |
100 | PRNT4-15.5/10 | XRNT4-15.5/31.5 | PRNT4-24/6.3 | XRNT4-24/16 | PRNT4-40.5/5 | XRNT4-40.5/10 |
200 | PRNT4-15.5/16 | XRNT4-15.5/40 | PRNT4-24/10 | XRNT4-24/20 | PRNT4-40.5/8 | XRNT4-40.5/16 |
315 | PRNT4-15.5/25 | XRNT4-15.5/50 | PRNT4-24/16 | XRNT4-24/32 | PRNT4-40.5/10 | XRNT4-40.5/20 |
400 | PRNT4-15.5/32 | XRNT4-15.5/63 | PRNT4-24/20 | XRNT4-24/40 | PRNT4-40.5/16 | XRNT4-40.5/31.5 |
500 | PRNT4-15.5/40 | XRNT4-15.5/80 | PRNT4-24/25 | XRNT4-24/50 | PRNT4-40.5/20 | XRNT4-40.5/40 |
630 | PRNT4-15.5/50 | XRNT4-15.5/100 | PRNT4-24/31.5 | XRNT4-24/63 | PRNT4-40.5/25 | XRNT4-40.5/50 |
800 | PRNT4-15.5/65 | XRNT4-15.5/125 | PRNT4-24/40 | XRNT4-24/80 | PRNT4-40.5/25 | XRNT4-40.5/50 |
1000 | PRNT4-15.5/80 | XRNT4-15.5/150 | PRNT4-24/50 | XRNT4-24/100 | PRNT4-40.5/31.5 | XRNT4-40.5/63 |
1250 | PRNT4-15.5/100 | XRNT4-15.5/175 | PRNT4-24/65 | XRNT4-24/125 | PRNT4-40.5/31.5 | XRNT4-40.5/63 |
1600 | PRNT4-15.5/140 | XRNT4-15.5/200 | PRNT4-24/80 | XRNT4-24/150 | PRNT4-40.5/40 | XRNT4-40.5/80 |
2000 | XRNT4-15.5/250 | PRNT4-24/100 | XRNT4-24/200 | PRNT4-40.5/50 | XRNT4-40.5/125 | |
250 | PRNT4-40.5/65 | SRNT4-40.5/125 |
Model and meaning
1.Are you manufacture?We are a professional factory with more than 20 years of experience,Our projects supplied to Airprot/Subway/Railway/power station.2.What is your technical advantages?Our engineers worked in the power distribution industry field for 20~30 years.In particular, in non-standard customization of electric field, High altitude, non-standard voltage frequency field.3.What is your price advantages?we have 5 branch factories for electric components,all raw materials are one stop shopping,so we can save the value for you!4.How about your quality advantage?We are 100% guarantee the quality for 3 years, provide 5% free rate of change.5.How about your delivery time?The delivery time with 1-6 working days after getting deposit. Our factory is located in Xi'an , China . In terms of quality and strength, we are both ahead of the market . 6.We can accept payment way:TT/LC/DP /STS ORDER